Search
United Kingdom +44 (0)1908 316345
United States +1 (210) 697 0335
sales@sonatest.com

RAILSCAN 125


Overview Specifications  

Ultrasonic Specifications Measurement Modes:

Test Range: 0 - 5mm (0.2in) up to 0 - 10000 mm (400 in.) at steel velocity. Variable in 1mm & 10mm steps.

Velocity: 1000 to 9,999m/s continuously variable.

Probe Zero: 0 to 999.999 μs, continuously variable.

Delay: Calibrated delay from 0-10000mm in 0.05 mm steps at steel velocity (0-400in. in 0.002 in. steps).

Gain: 0 to 110dB. Adjustable in 0.5, 1, 2, 6, 10, 14 and 20dB steps. Direct access to gain control at all times.

Test Modes: Pulse echo and transmit/receive.

Pulser: -200V square wave pulser. Pulse width 100ns. Rise/fall times <10ns into 50 ohms:

P.R.F: 1000 Hz.

Update Rate: 60Hz (NTSC Mode); 50Hz (PAL Mode).

Rectification: Full wave.

Frequency: Range 2.5MHz and 5.0MHz.

System Linearity: Vertical = 1% Full Screen Height (FSH). Amplifier Accuracy ±
0.1dB. Horizontal ±0.4% Full Screen Width (FSW).

Units: Metric (mm) or inch (in).

Display:

Display: Colour Transflective TFT: Display area 111.4 x 83.5 mm (4.39 x 3.29 in) 320 x 240 pixels. A-Scan Area 255 x 200 pixels (315 x
200 expanded), 8 colour options and variable brightness.

Gate Monitor: Two fully independent gates for echo monitoring and thickness measurement. Start and width adjustable over full range of unit,
amplitude variable from 0 to 100% FSH. Bar presentation. Positive triggering for gate 1 and negative triggering for gate 2, both with audible and visual alarms.

Gate Expansion: Expands range to width of Gate 1.

Gate Monitor Delay: Fixed 0.6 seconds delay on Gate 2 negative monitor tracking.

Measurement Modes:

Mode 1: Signal Monitor

Mode 2: Depth and amplitude of first signal in gate.

Mode 3: Echo-to-Echo distance measurement. (single gate)

Mode 4: Trigonometric display of beam path, surface distance and depth of indication, curve surface correction and X-OFFSET for probe index. Half skip indication on screen.

Mode 5: T-Min mode for holding minimum thickness reading.

Resolution: 0.01mm (0.001in) for distance measurement or 1% FSH for amplitude
measurement. Large display of measurement at the top of A-Scan display. Measurement mode selectable between peak and flank.

A-Scan Memory: Maximum of 800 waveforms can be printed or transferred to
a PC using optional SDMS software.

Panel Memory: 100 stores for retaining calibrations.

Thickness Logging: Storage for 8000 thickness readings configured either by Block/Location/Number mode or pre-programmable work sheets in sequential mode. Readings can be exported to MS Excel using optional SDMS software.

DAC: DAC defined by up to 10 points and digitally drawn on screen. DAC curves meet requirements of EN 1714, JIS and ASME standards, selectable between -2, -6, -10, -12 and -14dB. Amplitude read out selectable between % DAC or relative dB.

Auto-Cal: Provides automatic calibration from two echoes.

Clock: Sets time and date.

Notes: Alphanumeric labelling for panel and A-log allows the user to enter Notes for storage with panel settings and A-scans.

Display Freeze: For capturing the current A-scan image.

Peak Memory: For echo dynamic pattern determination.

Keylock: Prevents accidental alteration of parameters.

Help Key: For instant operator guidance on using the Railscan unit.

Language Support: Supports multiple languages. User selectable between English,
German, Spanish, French, Dutch, Italian, Russian, Polish, Czech, Finnish & Hungarian. Others available on request.

Waveform Smoothing: Gives a smooth signal envelope, simulating analogue equipment.

Outputs: Full bi-directional serial interface to transfer parameters, thickness
readings and waveform memories. Composite video, PAL or NTSC
compatibility.

External Alarm: Front mounted socket for attachment.

Printers: Supports any printer with PCL support including Hp DeskJet and Epson.

Power: Lithium Ion battery pack 14.4V, 5.0 ampere hours, gives up to 16 hours duration from a fully charged pack. Indication of low
battery status. Recharge time 3-4 hrs.

Charger: 100 - 240 VAC, 50-60Hz.

Transducer Sockets: BNC or LEMO (factory option)

Environmental: Case sealed to IP67

Temperature: Operating -10°C to +55°C (14 to 131°F). -20°C to +70°C. (-4 to 158°F) survivable.
Storage: -40° to +75°C. (-40 to = 167°F)

Physical:

Size: 255 x 145 x 145mm (10.0 x 5.7 x 5.7 in)

Weight: 2.5kg (5.5lbs) with Li-Ion cells.

Accessories:

Standard Kit Includes: Railscan 125R
Li-ion Battery & Battery Charger
Fabric Carry Bag
Calibration Certificate
Instruction Manual (EN12668)

Certification:

Calibration Certificate

 
Get a competitive quotation
Get a competitive quotation
(price) on this product from
Sonatest or one of our many
authorized distributors.


Request more information about this product. This may be technical queries, applications that this product is used in or any other information you require related to this product.
Request more information about
this product. This may be
technical queries, applications
that this product is used in or
any other information you
require related to this product.


View a brochure on this product.
View a brochure on this product.

News
News Feed Bookmark and Share
Copyright 2010 Sonatest Limited | Shipping and Returns | Disclaimer | Privacy and Data Protection Policy | Site Map