MASTERSCAN 350M
|
 |  | |
| Test Range | 0 - 1mm (0.05in) up to 0 - 20000 mm (800 in.) at steel | | Velocity | Variable in 1,2,5 sequence or continuously in 1mm(0.05in) increments. Also from 1 to 5000(μs). Velocity 256 to 16000m/s continuously variable. | | Probe Zero | 0 to 999.999 μs, continuously variable. | | Delay | Calibrated delay from 0 -20000mm in 0.05 mm steps at steel velocity (0-400in. in 0.002 in. steps). | | Gain | 0 to 110dB. Adjustable in 0.1, 0.5, 1, 2, 6, 10, 14 and 20dB steps. Direct access to gain control at all times. | | Test Modes | Pulse echo and transmit/receive. | | Pulser | 100V - 350V (450V MS380) square wave pulser. Pulse width from Spike to 2000ns duration - rise/fall times <5ns into 50 ohms: Width adjustable in 2% of nominal width, minimum 1ns maximum 40ns. | | ActiveEdge TM | Unique active pulse control for enhanced near surface resolution and signal response. Replaces traditional damping control. | | P.R.F | Selectable 5 to 5000 Hz. | | Update Rate | 60Hz (NTSC Mode); 50Hz (PAL Mode). | | Rectification | Full wave, positive or negative half wave and unrectified rf. | | Frequency Range | 6 narrow bands centred at 0.5 MHz, 1MHz, 2.25MHz, 5MHz, 10MHz and 15MHz. Broad band at 2 MHz to 22MHz (-6dB) and 1MHz to 35 MHz (-20dB). | | System Linearity | Vertical = 1% Full Screen Height (FSH). Amplifier Accuracy ± 0.1dB. Horizontal ±0.4% Full Screen Width (FSW). | | Reject | 80% linear reject. LED warning light when selected. | | Units | Metric (mm), inch (in) or time (μs). | | Display | Colour Transflective TFT: Display area 111.4 x 83.5 mm (4.39 x 3.29 in) 320 x 240 pixels. A-Scan Area 255 x 200 pixels (315 x 200 expanded), 8 colour options and variable brightness. | | Gate | Monitor Two fully independent gates for echo monitoring and thickness measurement. Start and width adjustable over full range of unit, amplitude variable from 0 to 100% FSH. Bar presentation. Positive or negative triggering for each gate with audible and visual alarms. | | Gate Expansion | Expands range to width of Gate 1. | | Gate Monitor | Delay Selectable 0.6 seconds delay on gate 2 negative monitor tracking. | | Measurement Modes | | | Mode 1 | Signal Monitor | | Mode 2 | Depth and amplitude of first signal in gate. | | Mode 3 | Echo-to-Echo distance measurement. (single gate) | | Mode 4 | Trigonometric display of beam path, surface distance and depth of indication, curve surface correction and X-OFFSET for probe index. Half skip indication on screen. | | Mode 5 | Gate to Gate distance measurement. (independent gates). | | Mode 6 | T-Min mode for holding minimum thickness reading. Resolution to 0.01mm (0.001in) for distance measurement or 1% FSH for amplitude measurement. Large display of measurement at top of A-Scan display. Measurement mode selectable between peak and flank. | | A-Scan Memory | Maximum of 800 waveforms can be printed or transferred to a PC using optional SDMS software. | | Panel Memory | 100 stores for retaining calibrations. | | Thickness Logging | Storage for 8000 thickness readings configured either by Block/Location/Number mode or pre-programmable work sheets in sequential mode. Readings can be exported to MS Excel using optional SDMS software. | | AGC | Automatic Gain Control automatically sets the signal to a level between 10-90% FSH with tolerance between 5-20% accuracy. |
| DAC | DAC defined by up to 10 points and digitally drawn on screen. DAC curves meet requirements of EN 1714, JIS and ASME standards, select able between -2, -6, -10, -12 and -14dB. Amplitude read out selectable between % DAC, % FSH or relative dB. | | TCG | Time Corrected Gain, also known as Swept Gain. 40dB dynamic range greater than 30dB per microsecond and up to 10 points may be used, setting all signals initially to 80% FSH. | | Back wall Echo Attenuation | 0- 40dB attenuation. | | AWS | Built in software for evaluation of defect indications in accordance with AWS D1.1 structural weld code. | | AVG/DGS | Automatic calculation from transducer data. | | API | Flaw sizing complying with API 5UE | | Auto-Cal | Provides automatic calibration from two echoes. | | Clock | Sets time and date. | | Reference Waveform | This menu displays a waveform from one of the A-log stores as a reference or fingerprint display in a colour different from the active display highlighting differences from the reference. | | Notes | Alphanumeric labelling for panel and A-log allows the user to enter Notes for storage with panel settings and A-scans. | | Display Freeze | For capturing the current A-scan image. | | Active Peak Memory | Envelope waveform for echo dynamic pattern determination, with simultaneous live A-scan display. | | Keylock | Prevents accidental alteration of parameters. | | Help Key | For instant operator guidance on using the Masterscan Series. | | Language Support | Supports multiple languages. User selectable between English, German, Spanish, French, Dutch, Italian, Russian, Polish, Czech, Finnish & Hungarian. Others available on request. | | Waveform Smoothing | Gives a smooth signal envelope, simulating analogue equipment. | | Outputs | Full bi-directional serial interface to transfer parameters, thickness readings and waveform memories. Composite video, PAL or NTSC compatibility. Analogue proportional outputs programmable to distance or amplitude of signal in the gate. Transmitter sync output | | Front USB | For connection to printers, keyboards and PC. | | Printers | Supports Hp DeskJet, Epson. | | Power | Lithium Ion battery pack 14.4V, 5.0 ampere hours, gives up to 16 hours duration from a fully charged pack. Indication of low battery status. Recharge time 3-4 hrs. Mains pack option. | | Charger | 100 - 240 VAC, 50-60 Hz. | | Transducer Sockets | BNC or LEMO (factory option) | | Environmental | Case sealed to IP67 | | Temperature | Operating -10°C to +55°C (14 to 131°F). -20°C to +70°C. (-4 to 158°F) survivable. | | Storage: | -40° to +75°C. (-40 to = 167°F) | | Size | 255 x 145 x 145mm (10.0 x 5.7 x 5.7 in) | | Weight | 2.5kg (5.5lbs) with Li-Ion cells. | | Standard Kit | Li-ion Battery & Battery Charger Fabric Carry Bag Calibration Certificate Instruction Manual (EN12668) |
|
|
|
|